RESULTS: After revision, the pain rating at rest (on a 0-10 numerical scale) decreased from 5.6 ± 1.3 to 1.1 ± 1.3 (P < .001) and pain during activity decreased from 7.4 ± 1.2 to 2.1 ± 1.8 (P < .001). The Oxford shoulder score improved from 47 ± 6 to 31 ± 9 (P < .001), and the subjective shoulder value (on a 0%-100% scale) improved from 22% ± 14% to 45% ± 18% (P < .001). Active shoulder range of motion was similar before and after revision. Postoperative complications occurred in 9 patients and included 1 infection, 2 periprosthetic fractures, 2 prosthetic dislocations, and 4 fixation screw fractures. No case of glenoid loosening occurred.
CONCLUSION: The CAD/CAM shoulder offers a reliable method of securing a glenoid component in shoulders with advanced glenoid deficiency and should be considered as an alternative to other surgical methods in these challenging cases. At 3 years' follow-up, pain and clinical scores improved significantly and no case of glenoid loosening occurred.

PMID: 23849676 [PubMed - as supplied by publisher]

Read more... http://www.ncbi.nlm.nih.gov/pubmed/23849676?dopt=Abstract