RESULTS: The average increase in abduction amplitude was 10° and inferior impingement occurred 18° later with a 42-mm glenosphere, especially when it was lateralized by 10 mm, relative to a 36-mm centered glenosphere (P < .05). These 2 combinations provided a 28° increase in the movement amplitude in the scapular plane. Positioning of the humeral component in 10° or 20° of retroversion or in anatomical retroversion was most effective at avoiding inferior impingement but had less effect on abduction range of motion (except with the 42-mm glenosphere).
CONCLUSION: Our study confirmed published results with various glenosphere designs but was unique in describing the effect of humeral retroversion on scapular impingement. Inferior scapular notching can be most effectively prevented by using large-diameter glenospheres with lateralized COR and by making sure to replicate the patient's native humeral retroversion.

PMID: 23850310 [PubMed - as supplied by publisher]

Read more... http://www.ncbi.nlm.nih.gov/pubmed/23850310?dopt=Abstract