from 0% to 97% per surgery. Fluoroscopy was significantly longer when the C-arm position was inverted when compared with the standard position (43 vs. 26 s, P=0.034). Surgeons' exposure to direct beam radiation was also slightly greater when the C-arm position was inverted (16% vs. 10%, P=0.087). The duration of fluoroscopy exposure and the percentage of films with the body exposed to radiation did not differ based on whether the surgery was performed by an attending, a resident, or both (P=0.53 and 0.28, respectively). However, the percentage of films with bodily radiation exposure did significantly differ between the attending physicians (P=0.029).
CONCLUSIONS:: Direct beam radiation exposure varied widely between surgeries and surgeons, ranging from none to nearly constant exposure. Surgical time also significantly increased with the C-arm in the inverted position compared with the standard position. Given the significant variation in exposure between attending physicians, it is likely that exposure to direct beam radiation can be avoided with improved awareness about the risk of direct beam radiation exposure and cautious surgical technique.
LEVEL OF EVIDENCE:: Not applicable.

PMID: 23995144 [PubMed - as supplied by publisher]

Read more... http://www.ncbi.nlm.nih.gov/pubmed/23995144?dopt=Abstract