RESULTS: At 5-year followup the KSS mean was 90.4 (range, 68-100; 95% CI, ± 1.6) for Group 1, and 86.5 (range, 56-99; 95% CI, ± 2.4) for Group 2. The effect size, at 95% CI for the difference between means, was 3.88 ± 2.87. The WOMAC mean was 15.1 (range, 0-51; 95% CI, ± 2.6) for the Group 1, and 19.1 (range, 4-61; 95% CI, ± 2.9) for Group 2. The effect size for WOMAC was -4.0 ± 3.9. There were no differences in the frequency of complications or in aseptic loosening between the two groups.
CONCLUSIONS: Our data suggest there are small differences between the uncemented porous tantalum tibial component and the conventional cemented tibial component. It currently is undetermined whether the differences outweigh the cost of the implant and the results of their long-term performance.
LEVEL OF EVIDENCE: Level I, therapeutic study. See Instructions to Authors for a complete description of levels of evidence.
PMID: 23884802 [PubMed - as supplied by publisher]
Read more... http://www.ncbi.nlm.nih.gov/pubmed/23884802?dopt=Abstract