METHODS: Eighty-three Oxford knee prostheses were implanted between September 2005 and July 2008 by the principal investigator. Radiographic and clinical data were available for review for all cases. A failed knee was defined as having recurrent pain after an earlier period of recovery from surgery, progressive radiolucent lines compared with initial postoperative radiographs, and a bone scan showing an isolated area of uptake limited to the area of the replaced compartment.
RESULTS: Eleven knees in this series failed (13%); Kaplan-Meier survivorship was 86.5% (95% CI, 78.0%-95.0%) at 5 years. Failure occurrences were distributed evenly over the course of the study period. No learning curve effect was identified.
CONCLUSIONS: Based on these findings, including a high failure rate of the Oxford knee implant and the absence of any discernible learning curve effect, the principal investigator no longer uses this implant.
LEVEL OF EVIDENCE: Level III, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.

PMID: 23907606 [PubMed - as supplied by publisher]

Read more... http://www.ncbi.nlm.nih.gov/pubmed/23907606?dopt=Abstract